Technical Overview
Verified OEM industrial spare part catalogued for petrochemical & MRO procurement.
Manufacturer:
SafeAir Technology
Category:
Unclassified
Sub-Category:
Needs Manual Review
Part Number:
PN-8339
Model Number:
MN-8339
Guaranteed Genuine OEM Industrial Part
Explosion Proof AC Unit
Part Number
PN-8339
Model Number
MN-8339
Category
Unclassified
Sub-Category
Needs Manual Review
Product Specification
We have quoted Matticks equivalent, the WCSK2® Series Safety King Explosion Proof Window or Thru-Wall A/C unit are engineered and manufactured to provide optimum performance in extreme and hazardous...
Availability Status:
In Stock (10 available)
Detailed Specifications & Description
We have quoted Matticks equivalent, the WCSK2® Series Safety King Explosion Proof Window or Thru-Wall A/C unit are engineered and manufactured to provide
optimum performance in extreme and hazardous environmental consistently. With capacities ranging from 6,000 -35,000 Btu/hr,
these units are idea for window or thru wall mounting applications in hazardous environments. The WCSK2® series system comply with the NEC / NFPA 70 Articles 500-515.
NRTL Third Party Certified by Intertek to UL484:2014Ed.9+R, CSA.222#117*, UL121201:2017Ed.3 and CSA CC22.2#213:2017Ed.3.
Specifications:
MODEL # : WCSK2S-10-1-3T
COOLING CAPACITY: 10,000 BTU/HR HEATING CAPACITY:N/A
A/C AIR FLOW :300 CFM
POWER SUPPLY: 115/1/60
MCA : 10.5 A
MOPD: 20 A
ELECTRICAL CLASSIFICATION:
CLASS I, GROUPS BCD, DIVISION 2 T3
STANDARD UNIT DETAILS:
Unit Constructed to meet NEC Classification
20 Gauge Enamel Coated Housing
Slide out chassis for permanent style installation
Power Whip – Can run to left or right side of unit
Washable, antimicrobial air filter
Totally Enclosed Fan Motor with Division 2 approved overload
Dense Insulation Installed to Block Outdoor Noise
Reduced Operating Noise by Component Vibration Isolation
Durable Base Pan & Steel Inner Walls
Environmentally friendly R410-A Refrigerant
STANDARD CONTROL DETAILS:
Anti-Short Cycle Timer Built in to Protect Unit Compressor
Refrigerant Pressure Safety Circuit (if equipped)
Manual Reset Heater Limit Safety Circuit (if equipped)
Shutdown Contacts for Unit Remote Shutdown
Solid State Design including power and control devices
Digital Temperature Controller
LCD Displays: Room & Set-point Temperature, Mode, Time Delay, Status, Remote Shutdown Status, Low & High Fan Speeds
DOCUMENTATION PROVIDED:
General Arrangement Drawing: SAT-SP/WC-DWG-M200, SAT-SP/WC-DWG-M201, SAT-SP/WC-DWG-M202
Electrical Drawing: SAT-SP/WC-DWG-E200
Installation, Operation and Maintenance Manual